|
Field/Laboratory/Industrial
Instruments, Controllers & Sensors
Multi-parameter Bench Meters
Please click above to view this range
pH, Reference, Conductivity, Redox,
Dissolved Oxygen, Ion Selective Electrodes, Calibration
Solutions,
Hollow Cathode
Lamps
and
Deuterium
Lamps
|
Portable Waterproof pH, Redox
(ORP), Conductivity, TDS and Salinity testers :
The very competitively priced R.M.S
IP67 waterproof pocket-sized pH, Redox (ORP), Conductivity, TDS and
Salinity testers are the WORLD'S FIRST testers to utilize
user-replaceable electrodes to enhance the useful lifespan of the
instruments. These feather-weight testers are most ideal for rugged
outdoor use and wet applications. Newer
version testers feature large screen display and simultaneous
temperature readout, our new pH Spear tester (designed for use with
food applications has a unique double junction electrode using
special polymer gel electrolyte to provide reliable performance and
quick stable results needed for difficult samples.
We offer an extended 2 year warranty on our range of Pocket Testers.
Please click on the appropriate
link from the one of the following tables for full details :

pH :
| Model |
Accuracy |
Resolution |
ATC |
Display |
Calibration
Points |
Electrode |
|
pH
Spear
(NEW - For food application) |
±0.01
pH |
0.01
pH |
No |
Large
dual line display |
Up
to 3 points |
Spear
tip double junction replaceable |
|
pHTestr
10 (NEW) |
±0.1 pH |
±0.1 pH |
Yes |
Large
dual line display |
3 point
push-button
(USA, NIST) |
Double junction
replaceable |
|
pHTestr
20 (NEW) |
±0.01 pH |
±0.01 pH |
Yes |
Large dual line
display |
3 points
push-button
(USA, NIST) |
Double junction
replaceable |
pHTestr
30 (NEW)
(temp. readout) |
±0.01 pH |
±0.01 pH |
Yes |
Large dual line
display |
3 points
push-button
(USA, NIST) |
Double junction
replaceable |
|
pHTestr
10BNC (NEW) |
±0.01 pH |
±0.01 pH |
No |
Large dual line
display |
3 points
push-button
(USA, NIST) |
Use with
electrode
with BNC connector |
|
pHScan
WP1 |
±0.2 pH |
±0.1 pH |
No |
Single line
display |
1 point
push-button (USA) |
Single junction
replaceable |
|
pHScan
WP2 |
±0.1 pH |
±0.1 pH |
Yes |
Single line
display |
3 points
push-button (USA) |
Single junction
replaceable |
|
pHScan
WP3 |
±0.02 pH |
±0.01 pH |
Yes |
Single line
display |
3 points
push-button
(USA, NIST) |
Double junction
replaceable |
pHScan
WP3+
(temp. readout) |
±0.02 pH |
±0.01 pH |
Yes |
Single line
display |
3 points
push-button
(USA, NIST) |
Double junction
replaceable |
|
pHScan
WPBNC |
±0.05 pH |
±0.01 pH |
No |
Single line
display |
3 points
push-button
(USA, NIST) |
Use with
electrode
with BNC connector |
Redox (ORP) :
| Model |
Accuracy |
Resolution |
Display |
Calibration
Points |
Electrode |
ORPTestr
10
(NEW) |
±2
mV |
±1
mV |
Large
dual line display |
Offset
push-button
( ±150 mV) |
Double
junction replaceable |
|
ORPTestr
10BNC
(NEW) |
±2
mV |
±1
mV |
Large
dual line display |
Offset
push-button
( ±150 mV) |
Use
with electrode
with BNC connector |
|
ORPScan
WP |
±2
mV |
±1
mV |
Single
line display |
Offset
push-button
( ±150 mV) |
Double
junction replaceable |
Conductivity (EC)
|
Model |
Range |
Accuracy |
Calibration
Points |
Electrode |
ECTestrHigh+
(NEW) |
0 to 19.99 mS/cm |
± 1% of Full Scale |
1 point |
Scoop and dip type
replaceable |
ECTestrLow+
(NEW) |
0 to 1999 µS/cm |
± 1% of Full Scale |
1 point |
Scoop and dip type
replaceable |
ECTestrPure+
(NEW) |
0 to 199.9 µS/cm |
± 1% of Full Scale |
1 point |
Scoop and dip type
replaceable |
ECTestrHigh
(NEW) |
0 to 19.90 mS/cm |
± 1% of Full Scale |
1 point |
Dip type
replaceable |
ECTestrLow
(NEW) |
0 to 1990 µS/cm |
± 1% of Full Scale |
1 point |
Dip type
replaceable |
|
ECScan
High+
(temp. readout)
|
Up to 19.99 mS/cm |
±1% full scale |
1 point
push-button |
Scoop and dip
type replaceable |
|
ECScan
Low+
(temp. readout)
|
Up to 1999 µS/cm |
±1% full scale |
1 point
push-button |
Scoop and dip
type replaceable |
|
ECScan
Pure+
(temp. readout)
|
Up to 199.9 µS/cm |
±1% full scale |
1 point
push-button |
Scoop and dip
type replaceable |
|
ECScan
High
|
Up to 19.90 mS/cm |
±1% full scale |
1 point
push-button |
Dip type
replaceable |
|
ECScan
Low
|
Up to 1990 µS/cm |
±1% full scale |
1 point
push-button |
Dip type
replaceable |
|
TDScan
WP4 |
Up to 19.90 mS/cm |
±2% full scale |
1 point trimmer |
Dip type
built-in |
|
TDScan
WP3 |
Up to 1990 µS/cm |
±2% full scale |
1 point trimmer |
Dip type
built-in |
Total Dissolved Solids (TDS)
| Model |
Range |
Accuracy |
Calibration
Points |
Electrode |
|
TDScan
High+
(temp. readout)
|
Up
to 10.00 ppt |
±1%
full scale |
1
point push-button |
Scoop
and dip type replaceable |
|
TDScan
Low+
(temp. readout)
|
Up
to 1999 ppm |
±1%
full scale |
1
point push-button |
Scoop
and dip type replaceable |
|
TDScan
Pure+
(temp. readout)
|
Up
to 199.9 ppm |
±1%
full scale |
1
point push-button |
Scoop
and dip type replaceable |
|
TDScan
High
|
Up
to 10.00 ppt |
±1%
full scale |
1
point push-button |
Dip
type replaceable |
|
TDScan
Low
|
Up
to 1990 ppm |
±1%
full scale |
1
point push-button |
Dip
type replaceable |
|
TDScan
WP2 |
Up
to 10.00 ppt |
±2%
full scale |
1
point trimmer |
Dip
type built-in |
|
TDScan
WP1 |
Up
to 1990 ppm |
±2%
full scale |
1
point trimmer |
Dip
type built-in |
Salinity
| Model |
Range |
Accuracy |
Calibration
Points |
Electrode |
|
SaltTestr10 |
0
to 10.00 ppt |
±1%
full scale |
1
point (±50% window from factory default) |
Dip
type replaceable |
|
SaltScan
|
Up
to 10.00 ppt |
±1%
full scale |
1
point push-button |
Dip
type replaceable |
|